Address:Block 15, Guangqian 1st Industrial Zone, Longzhu 3rd., Xili Town, Nanshan District, Shenzhen City, China Zip:518055
STO-184-200-Type Testing Module is the most updated patented high-density testing and connection developed by ourselves. It adopts the Insulation Displacement Connection termination technology to realize flexible and reliable connection between IDSLAM exchanger cable and outer module, i.e. subscriber cable for jumper and test etc. functions. Especially in construction and development of XPSL broadband traffics, it is applied vastly in places having quite high requirements on density of distribution wires. Technical performance: Work temperature: +5 ~ +40℃ Relative humidity: <85%(+30℃) Atmospheric pressure: 70~106Kpa Insulated resistance: ≥6000MΩ Dielectric strength: 1000V(45~60Hz)/1min no spark, no flash over
Terminal contact resistance: ≤0.8mΩ, increment of contact resistance after high temperature, low temperature, temperature fluctuation, damp heat and vibration test: ≤0.6mΩ Air tightness: Uncorrupted area occupies>55% of the total area Pull-out force: The Pull-out force of single wire along vertical direction of the module is >28N Plug-pull life: >200 times Plastic inflammability: All plastic parts and components are of great quality flame retardant, its performance meet the A-class standard of GB/T5169.7 Other index reaches the industry standard of YD/T694-1999《Main Distribution Frame》